Technical Information

Technical Specifications

Elematic SA’s hollow core concrete slabs are designed and manufactured with precision, using world class technology. A variety of slab thicknesses and widths are available and can be used in combinations to suit the requirements of every project.
We manufacture prestressed hollow core concrete slabs in a variety of different slab types and thicknesses. All slabs have a standard 1 hour fire rating, but higher fire ratings can be achieved if required.
Slab panel thickness120mm150mm200mm250mm
Standard width1200mm1200mm1200mm1200mm
Area of cross section0.100482 mm²0.099222 mm²0.119619 mm²0.149209 mm²
Theoretical weight of slab215kg/mm²220kg/mm²270kg/m²340kg/m²

Material properties:

Accepted bearing tolerances:

Design parameters:

Serviceability live load versus span diagrams are available for use in the project budget phase. We do recommend, however, that architectural and/or engineering drawings be forwarded to the Elematic SA design team (info@elematicsa.co.za) for a confirmed budget quotation.

Cross sections to the different available prestressed slab thicknesses are available on request.

Steel Applications

Where steel is required for structural support, Elematic SA slabs can easily be incorporated in a variety of configurations. For more information on this please contact us.

Typical steel support solutions can range from a conventional downstand support beam (beam below the hollow core slab soffit) or an upstand beam where the beam is located within the slab thickness (with only the beam bottom flange visible from below).

Design Parameters

Site Applications and Requirements

Screeding

On contracts where hollow core slabs are used indoors and no structural topping is specified a simple 40 – 50mm levelling screed is required.

All loose material is to be removed from the tops of the slabs, which should be thoroughly wetted and screed applied immediately. The levelling screed should comprise 1:4 mix by volume of cement to clean river sand. Water should be added to the mixture to an extent that the mixture is relatively dry but remains easy to float finish.
The screed should be laid to an approximate thickness of 40 – 50mm. After laying the screed it should be steel floated and then wetted for 48 hours to prevent shrinkage cracks.

Further technical information on this procedure is available on request. We are happy to discuss your particular requirements with you.

Lighting

A variety of lighting options can be utilised with Elematic SA's prestressed hollow core concrete slabs. Further technical information on this procedure is available on request.

Fire Ratings

All our slabs come standard with a one hour fire rating, which can be increased to a two hour rating if required.

Tiling

Further technical information on this procedure is available on request.

South Africa’s leading manufacturer of precast concrete products.

Contact us for helpful and experience-backed advice about any projects you have. We are available to assist with project solutions. All compliance assessments and certifications are available on request.